ELECTRICAL SPECIFICATION - Revised 03/15/18

 

WE REQUIRE:

  • A Cutler Hammer, or equivelent, service disconnect box. Disconnect box may be fused or fuseless.
  • Requires 208 or 240 VOLT, 3-PHASE, Capable of 60 amps or larger.  
  • Winery power is feeding a “sub-panel” in our bottling trailer.
  • TThe service disconnect box must have dedicated ground wire to the inside of the service disconnect box with a connection lug, and dedicated neutral wire from panel to the service disconnect box with a connection lug. Both the ground and neutral wires require separate 4 gauge lugs inside disconnect box for us to connect. It is ABSOLUTELY REQUIRED, to have a dedicated ground wire lug, and neutral wire lug.
  • Please locate disconnect box within 100 feet of bottling truck.

We have 130 feet of power cord from our truck to reach the winery.

    INSTALLER NOTE: Please wire 3 hot legs to box, with a separate ground, and separate neutral wire to 4 gauge lugs. (5 wires total). Each line to disconnect must read 116-120volts to ground, and 208-240 volts line to line. DO NOT USE CONDUIT AS GROUND, PLEASE USE DEDICATED WIRE OF APPROPRIATE SIZING FOR 60 AMPS.

    IF YOUR WINERY DOES NOT HAVE 3-PHASE POWER.

    • YOU MAY RENT A GENERATOR FROM A LOCAL EQUIPMENT RENTAL COMPANY.
    • 2The Generator should be at least a 40 Kilowatt Unit or larger.
    • We will hook a pigtail to generator lugs, then plug the truck into the pigtail.
    • 208 or 240 3-PHASE, @ 60 AMPS.
    • THE EQUIPMENT COMPANY WILL USUALLY DELIVER AND PICK UP FOR YOUR CONVENIENCE

    ANY QUESTIONS? CALL 1-888-268-8548. DAVID SCHOLZ